These test methods measure the arc thermal performance value of materials which meet the following requirements: less than 100 mm char length and less than 2 s afterflame after removal from flame, when tested in accordance with ISO 15025, procedure B (bottom-edge ignition) on the outer material, and the char length measured using a modified ISO method as described in Annex A.
These methods are used to measure and describe the properties of material, products, assembled or garments in response to convective and radiant energy generated by an electric arc in open air under laboratory conditions.