These requirements cover metallic and nonmetallic chimney liners intended for field-installation into new o r existing masonry chimney s that are used for the natural draft venting of gas-, liquid-, and solid-fuel-fired residential-type appliances in which the maximum continuous flue-gas outlet temperatures do not exceed 1000 F (538 C).
Chimney liners are intended to be installed in existing masonry chimneys with or without a liner of fire-clay tile, or to be used as a substitute for masonry fire-clay tile flue liners in new chimneys.
Chimney liners are intended to be installed in accordance with the Standard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances, NFPA 211; and codes such as the BOCA National Mechanical Code, th e Standard Mechanical Code, and the Uniform Mechanical Code.
Chimney liners as covered by these requirements are not intended for use with Category II, III, or IV gas burning appliances as defined by the National Fuel Gas Code, NFPA 54, or other appliances that result in condensation of corrosive acids on the liner of the chimney, or that create positive pressures in the chimney system.
A product that contains features, characteristics, components, materials, or systems new or different from those in use when the Standard was developed, and that involves a risk of fire, electric shock, or injury to persons, shall be evaluated using the appropriate additional component and end-product requirements as determined necessary to mai ntain the level of safety for the user of the product as originally anticipated by the intent of this Standard.