Occupant behavioural scenarios are linked to design fire scenarios. Guidance on the selection of design fire scenarios and design fires is covered in ISO 16733-1. The steps in ISO 16733-1 are followed in this Technical Specification with life safety of the occupants as the single fire safety objective under consideration.
ISO/TR 16738 provides information on methods for the quantification of the different aspects of human evacuation behaviour in a design context. One part of that process involves the selection of occupant behavioural scenarios. This Technical Specification provides guidance for that aspect of the evaluation of an egress design.
This Technical Specification addresses behaviours that occur after fire ignition and does not deal with behaviours that influence fire ignition.
Cross References:
ISO 13571:2012
ISO 13943
ISO 16733-1:2015
ISO/TR 16738
ISO 16312-1
ISO/TR 16312-2
ISO 16732-1:2012
ISO 19706
ISO 21542
ISO 23932:2009
ISO 27368
IEC 60695-7-1
All current amendments available at time of purchase are included with the purchase of this document.