NOTE The overall safety requirements for the various types of equipment and installations for electroheating or electromagnetic processing in general result from the joint application of the General Requirements specified in IEC 60519-1:2015 and Particular Requirements covering specific types of installations or equipment. This technical specification complements the General Requirements and applies to internal frequency converters for creating high or low DC voltages, and to processing frequencies.
Induced electric shock phenomena dealt with in this technical specification are caused by the alternating magnetic nearfield external to a current-carrying conductor or permeable object, inducing an electric field in a part of the body in the vicinity of the conductor.
Relaxed criteria compared with the general basic restrictions for exposure apply. Simplified hazard assessment procedures apply for situations when only fingers, hands and/or extremities are in the magnetic nearfield.
This technical specification does not apply to equipment within the scope of IEC 60519-9. i.e. equipment or installations for high frequency dielectric heating.
Cross References:
IEC 60417
IEC 60519-1:2015
IEC 60050
IEEE C95.1:2005
IEC 60519
IEEE C95.6:2002
IEEE C95.3.1:2010
IEEE C95.1a:2010
IEC 60050-161:1990
IEC 62110:2009
IEC 61140:2016
IEC 60519-9:2005
IEC 62209-2:2010
IEC TS 62996:2017
IEC TS 60479-2:2007
IEC 60519-6:2011
EN 50445:2008
EN 50444:2008
IEC 60050-903:2013 ED1
IEC 62822-2:2016
IEC 60050-841:2004 Ed 2
IEC 62479:2010
IEC 62226-2-1:2004 Ed 1