1.1This practice defines procedures for measuring the thickness of uncoated steel sheet and nonmetallic and metallic-coated steel sheet. Thickness is a significant quality characteristic of steel sheet products. The ability to accurately measure thickness using hand micrometers is critical in determining product conformance to specifications. The methods described are designed and intended for use in both laboratory and plant situations and their environments.
1.2The flat steel product shall conform to all the requirements of the appropriate specifications as follows: Specifications A109/A109M, A505, A568/A568M, A635/A635M, A684/A684M, and A924/A924M.
1.3Quantitative limits are not addressed and are established in the general requirements, or individual product specifications, or both; or when applicable, as agreed to between supplier and user.
1.4This specification is applicable to orders in either inch-pound units or SI units. Values in inch-pound and SI units are not necessarily equivalent. Within the text, SI units are shown in brackets. Each system shall be used independently of the other.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.