This Code does not apply to component testing, for example, gas turbines (ASME PTC 22) or steam turbines (ASME PTC 6 or ASME PTC 6.2) or other individual components. To test a particular power plant or cogeneration facility in accordance with this Code, the following must be met:
(a) a means must be available to determine, through either direct or indirect measurements, all of the heat inputs entering the test boundary and all of the electrical power and secondary outputs leaving the test boundary;
(b) a means must be available to determine, through either direct or indirect measurements, all of the parameters to correct the results from the test to the base reference condition;
(c) the test result uncertainties should be less than or equal to the uncertainties given in subsection 1-3 for the applicable plant type; and
(d) the working fluid for vapor cycles must be steam.
This restriction is imposed only to the extent that other fluids may require measurements or measurement methods different fromthose provided by this Code for steam cycles.