This Code specifies procedures for conducting tests to determine the following performance characteristics of hydraulic turbine speed governors:
(a) droop:
(1) permanent,
(2) temporary;
(b) deadband and deadtime:
(1) speed,
(2) position,
(3) power;
(c) stability index:
(1) governing speedband,
(2) governing powerband;
(d) step response;
(e) gain:
(1) proportional gain,
(2) integral gain,
(3) derivative gain;
(f) setpoint adjustment:
(1) range of adjustment,
(2) ramp rate.
This Code also establishes the rules and procedures for the conduct of tests to determine the following operational characteristics of hydraulic turbine speed governors:
(a) gate/blade relationship (dual regulated reaction turbines),
(b) needle/deflector relationship (impulse turbines),