This RP includes the cavern well system (wellhead, wellbore, and cavern) from the emergency shutdown (ESD) valve down to the cavern and facilities having significant impact to safety and integrity of the cavern system. This RP may be applied to existing facilities at the discretion of the user.
This RP does not apply to caverns used for the storage of liquid or liquefied petroleum products, brine production, or waste disposal; nor to caverns which are mechanically mined, or depleted hydrocarbon or aquifer underground gas storage systems.
This document was written to provide a technical reference for the development and operations of solution-mined salt caverns and is not intended to represent or reflect any Federal, State, or local regulatory requirement. Depending on location and nature of the project, the recommended practices herein may address items that are in conflict with some regulatory requirements. If this occurs, the regulatory requirement supersedes the recommended practice unless an appropriate waiver or variance is granted from the issuing agency. A thorough review of the applicable Federal, State, and local rules and regulations is to be performed prior to the design of solution-mined natural gas storage caverns to ensure ongoing compliance.