1.1This practice covers the basic apparatus, procedures, and conditions required to create and maintain the severe wastewater analysis testing apparatus used for testing a protective coating or lining.
1.2This apparatus may simulate the pertinent attributes of a typical domestic severe wastewater headspace (sewer) environment. The testing chamber comprises two phases: (1) a liquid phase containing a prescribed acid and saline solution, and (2) a vapor phase consisting of air, humidity, and concentrated sewer gas (Note 1). The temperature of the test chamber is elevated to create accelerated conditions and reaction rates.
1.3Caution-This practice can be extremely hazardous. All necessary precautions need to be taken when working with sewer gas, sulfuric acid, and a glass tank. It is highly recommended that a professional testing laboratory experienced in testing with hydrogen sulfide, carbon dioxide, and methane gases perform this practice.
1.4The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Some specific hazards statements are given in Section 8 on Hazards.