As an alternative to selection of tested assemblies, this Standard provides methods to calculate the fire resistance of selected structural member and barrier assemblies using structural steel, plain concrete, reinforced concrete, timber and wood, concrete masonry, and clay masonry.
These methods are intended to provide architects, engineers, building officials, and others with calculation methods that will give the equivalent fire resistance that would have been achieved in the ASTM E119 standard fire test.