1.1 This test method covers a procedure for continuous immersion exfoliation corrosion testing of 5XXX series aluminum-magnesium alloys containing 2.0% or more magnesium.
1.2 This test method applies only to wrought products.
1.3 The values stated in SI units are to be regarded as the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.