This technical specification has historically been applied to rigid modules. It cannot be applied to flexible modules unless they are designed to be mounted in a rigid manner. In which case, the cyclic (dynamic) mechanical load test can be applied to the flexible module in its rigid mounting system.
This test has been written as a standalone technical specification, but it is likely to be used in conjunction with other test standards. Typically, this test itself will not result in power loss, but when followed by additional stress tests like thermal cycling and humidity freeze, the damage done by the mechanical cycling results in power loss that would not have occurred due only to the thermal cycling and humidity freeze tests. For example, the transportation testing procedure (IEC 62759) includes the requirements for such a cyclic (dynamic) mechanical load test followed by 50 thermal cycles and 10 humidity freeze cycles.
Cross References:
IEC TS 60904-12
IEC TS 60904-13
IEC 61215-1:2016
IEC 61215-2:2016
IEC TS 61836
ISO/IEC 17025